No. Grapevine requires a Knox remote power box at electric vehicle charging locations, but one- and two-family homes and their accessory buildings are exempt.
It must be listed and labeled to UL 2200 and connected by an approved method with listed materials. Generators for continuous, non-emergency use are prohibited.
Only if it is listed and labeled by a nationally recognized testing laboratory, or field evaluated by an approved agency. Grapevine’s amendment to the electrical code adds a note that a manufacturer’s self-certification may not meet U.S. product safety standards.
Minor repair work, such as replacing lamps or plugging approved portable equipment into permanent receptacles, is exempt. Other electrical repairs are simple trade permits, which Grapevine’s building department aims to issue the same day.
The city’s inspection procedures have the inspector confirm that open slots in the panel cover are filled or blanked, that each breaker is labeled with the circuit it serves, and that arc-fault and GFCI protection test correctly. GFCI protection is required in the garage, bathrooms, at kitchen counters and outdoors.